The H series high-power galvanometer welding system is independently developed by Soing Motion Department. All components are strictly tested and inspected before assembling. Through water-cooling circulation system and excellent sealing, the welding system can be operated under harsh conditions. The maximum power handling can be up to 6kW. Soing H series galvanometer scanner is a 30mm diameter high-power galvanometer scanner. In high-precision laser marking applications, the galvanometer is required to have excellent linearity, minimal temperature drift, and extremely high repeatability.
In order to meet the stringent requirements of high-precision applications, Soing scanner head relies on high-precision imported processing equipment, exquisite process systems, and rigorous quality control systems to overcome these harsh technical problems. This galvanometer has been widely used in the fields of laser marking, cutting, and welding.
Â
Â
1. High power up to 6000w
2. 20mm to 30mm aperture available
3. QBH connector and CCD adapter
4. Coaxial visual monitoring
5. Reliable water-cooling and air-cooling systems
6. Complete security and monitoring alarm function
Â
Â
One of the most important applications of the Galvo Scanner System is laser welding. Laser welding is a process that has been used in various industries, such as automotive, electronics, aerospace, and even jewelry making. The Galvo Scanner System is essential in laser welding because it allows for precise control of the laser beam, which is necessary to achieve high-quality welds.
The Galvo Scanner System used in laser welding systems is designed to handle high power outputs of up to 6000w. Additionally, the system has an aperture that ranges from 20mm to 30mm, making it suitable for various welding applications. The system also has a QBH connector and CCD adapter, which provides an excellent visual monitoring system, allowing welders to have a clear view of the welding process.
Â
Â
Model |
SPH20 |
SPH30A |
SPH30G |
Input Beam Aperture (mm) |
10 |
12 |
14 |
Typical Scan Angle (rad) |
±0.35 |
±0.35 |
±0.35 |
Tracking Error (ms) |
0.45 |
0.53 |
0.53 |
Step Response Time (ms) |
 |  |  |
1% Of Full Scale |
0.9 |
1.1 |
1.1 |
10% Of Full Scale |
2.5 |
4.0 |
4.0 |
Repeatability (μrad) |
<4 |
<4 |
<4 |
Long-terms Drift Over 8hours (mrad)¹ |
<0.3 |
<0.3 |
<0.3 |
Marking speed (mm/s)² |
1000 |
700 |
700 |
Positioning Speed (m/s) |
5 |
3 |
3 |
Power Requirements |
±15VDC/3A |
±15VDC/3A |
±15VDC/3A |
Digital Interface |
XY2-100 |
XY2-100 |
XY2-100 |
Weight (Kg) |
3.8 |
12 |
12 |
Dimension (L x W x H mm³) |
316x102x304 |
376x158x342 |
376x140x342 |
Â
Â
http://www.soingphotonics.com/